How a generator gets nitrogen out of the air, which means purity. 95 % against 99,999 And where every class really needs to be.
Nitrogen station makes nitrogen in place from normal compressed air — free of cylinders, delivery and dependence on the gas supplier. Let's figure out how this works and why "Normal Purity" — The main parameter on which both price and applicability depend.
Atmospheric air — That's about 78 % nitrogen and 21 % oxygen. The generator divides them physically by passing the prepared compressed air through an adsorbent or membrane that "hold" oxygen and send nitrogen. On the way out — N flow of specified purity under pressure.
PSA generators (short-cycle adsorption) use carbon molecular sieve and provide high purity — up to 99,999 %. The membrane stations are compacter and simpler, but economically reasonable to the point of order. 99,5 %. The choice between them — This is the balance between the required purity, consumption and operating conditions.
The higher the purity required, the more air is needed for each cubic metre of nitrogen and the larger the station. Overdue Cleanness requirement — frequent reason for overpayment. Take class to real task.
The station is selected in three parameters simultaneously: productivity (nm3/hour), purity (%) and working pressure (bar). A compressed air source, a drainage, nitrogen resivers and a pressure booster are further designed as necessary. It's always a system, not one machine.
Report performance, purity and pressure — We'll figure out the station and the whole bandage.